The N2XRY can be installed indoors, outdoors and underground, in pipes or in open environments where mechanical protection or high tensile forces are required during installation and operation. Because its conductors can withstand higher temperatures, it can be used in higher temperature environments.
Application and description
The N2XRY can be installed indoors, outdoors and underground, in pipes or in open environments where
mechanical protection or high tensile forces are required during installation and operation. Because its
conductors can withstand higher temperatures, it can be used in higher temperature environments.
Standards and certification
IEC 60502-1, VDE 0276-604, BS5467
Cable structure
- Solid or multiple strands of bare copper conductor
- Follow DIN VDE 0295 cl.1/cl.2, BS 6360 cl.1/cl.2, IEC 60228 cl.1/cl.2
- Crosslinked polyethylene 2XI1 class, according to VDE 0276-604
- Color coding according to DIN VDE 0293(HD 308)
- PVC filling
- Galvanized steel wire/aluminum wire armouring
- PVC outer sheath DMV5, following HD 603.1
Technical characteristics
- Operating voltage: 600/1000 V
- Test voltage: 3500 V
- Minimum bending radius: 15 x Ø
- Operating temperature: -5º C ~ +70º C
- Fixed installation temperature: -30 º C to +70º C
- Flame retardant: IEC 60332.1
- Insulation resistance: >20 MΩ x km
Cable parameter
|
Core number x conductor Cross area # x mm² |
Conductor type |
Sheath thickness Mm |
Communication conductor Cross area mm² |
Nominal outside diameter Mm |
Cable weight kg/km |
|
1x25 |
rm |
0.9 |
1.8 |
16.6 |
503 |
|
1x35 |
rm |
0.9 |
1.8 |
17.7 |
612 |
|
1x50 |
rm |
1 |
1.8 |
19.5 |
783 |
|
1x70 |
rm |
1.1 |
1.8 |
21.5 |
1014 |
|
1x95 |
rm |
1.1 |
1.8 |
23.5 |
1280 |
|
1x120 |
rm |
1.2 |
1.8 |
26.0 |
1575 |
|
1x150 |
rm |
1.4 |
1.8 |
27.5 |
1872 |
|
1x185 |
rm |
1.6 |
1.8 |
30.0 |
2294 |
|
1x240 |
rm |
1.7 |
1.9 |
33.0 |
2923 |
|
1x300 |
rm |
1.8 |
2.1 |
36.0 |
3509 |
|
1x400 |
rm |
2 |
2 |
40.5 |
4534 |
|
1x500 |
rm |
2.2 |
2.3 |
45.0 |
5691 |
|
1x630 |
rm |
2.4 |
2.5 |
49.5 |
7267 |
|
1x800 |
rm |
0.7 |
1.8 |
56.5 |
9271 |
|
2x1.5 |
re/rm |
0.7 |
1.8 |
13.6 |
325 |
|
2x2.5 |
re/rm |
0.7 |
1.8 |
14.5 |
379 |
|
2x4 |
re/rm |
0.7 |
1.8 |
15.7 |
448 |
|
2x6 |
re/rm |
0.7 |
1.8 |
16.8 |
530 |
|
2x10 |
rm |
0.7 |
1.8 |
19.4 |
783 |
|
2x16 |
rm |
0.7 |
1.8 |
22.0 |
982 |
|
2x25 |
rm |
0.9 |
1.8 |
25.5 |
1447 |
|
2x35 |
rm |
0.9 |
1.8 |
28.0 |
1765 |
|
2x50 |
rm |
1 |
1.9 |
30.5 |
2106 |
|
2x70 |
rm |
1.1 |
2 |
35.0 |
2765 |
|
2x95 |
rm |
1.1 |
2..2 |
39.5 |
3746 |
|
2x120 |
rm |
1.2 |
2.3 |
43.5 |
4465 |
|
2x150 |
rm |
1.4 |
2.5 |
47.5 |
5303 |
|
2x185 |
rm |
1.6 |
2.6 |
54.0 |
6890 |
|
2x240 |
rm |
1.7 |
2.8 |
59.5 |
8463 |
|
2x300 |
rm |
1.8 |
3.1 |
65.0 |
10151 |
|
3x1.5 |
re/rm |
0.7 |
1.8 |
14.1 |
351 |
|
3x2.5 |
re/rm |
0.7 |
1.8 |
15.1 |
415 |
|
3x4 |
re/rm |
0.7 |
1.8 |
16.3 |
503 |
|
3x6 |
re/rm |
0.7 |
1.8 |
17.5 |
603 |
|
3x10 |
rm |
0.7 |
1.8 |
20.5 |
903 |
|
3x16 |
rm |
0.7 |
1.8 |
23.0 |
1161 |
|
3x25 |
rm |
0.9 |
1.8 |
27.0 |
1709 |
|
3x35 |
rm |
0.9 |
1.8 |
29.5 |
2127 |
|
3x50 |
sm |
1 |
1.9 |
31.5 |
2424 |
|
3x70 |
sm |
1.1 |
1.9 |
36.5 |
3438 |
|
3x95 |
sm |
1.1 |
2 |
40.0 |
4343 |
|
3x120 |
sm |
1.2 |
2.2 |
43.5 |
5172 |
|
3x150 |
sm |
1.4 |
2.3 |
49.5 |
6675 |
|
3x185 |
sm |
1.6 |
2.5 |
54.0 |
7977 |
|
3x240 |
sm |
1.7 |
2.6 |
60.0 |
9995 |
|
3x300 |
sm |
1.8 |
2.8 |
65.0 |
11990 |
|
4x1.5 |
re/rm |
0.7 |
1.8 |
14.9 |
395 |
|
4x2.5 |
re/rm |
0.7 |
1.8 |
16.0 |
470 |
|
4x4 |
re/rm |
0.7 |
1.8 |
17.4 |
575 |
|
4x6 |
re/rm |
0.7 |
1.8 |
19.5 |
798 |
|
4x10 |
rm |
0.7 |
1.8 |
22.0 |
1058 |
|
4x16 |
rm |
0.7 |
1.8 |
25.5 |
1518 |
|
4x25 |
rm |
0.9 |
1.8 |
29.0 |
2055 |
|
4x35 |
rm |
0.9 |
1.9 |
32.0 |
2585 |
|
4x50 |
sm |
1 |
2 |
35.5 |
3040 |
|
4x70 |
sm |
1.1 |
2.1 |
41.0 |
4305 |
|
4x95 |
sm |
1.1 |
2.2 |
45.0 |
5476 |
|
4x120 |
sm |
1.2 |
2.4 |
51.5 |
7064 |
|
4x150 |
sm |
1.4 |
2.5 |
57.5 |
8536 |
|
4x185 |
sm |
1.6 |
2.7 |
61.5 |
10189 |
|
4x240 |
sm |
1.7 |
2.8 |
68.0 |
12772 |
|
4x300 |
sm |
1.8 |
3 |
73.5 |
15380 |
|
5x1.5 |
re/rm |
0.7 |
1.8 |
15.8 |
441 |
|
5x2.5 |
re/rm |
0.7 |
1.8 |
17.0 |
535 |
|
5x4 |
re/rm |
0.7 |
1.8 |
19.3 |
768 |
|
5x6 |
re/rm |
0.7 |
1.8 |
21.0 |
921 |
|
5x10 |
rm |
0.7 |
1.8 |
23.5 |
1235 |
|
5x16 |
rm |
0.7 |
1.8 |
27.0 |
1765 |
|
5x25 |
rm |
0.9 |
1.8 |
31.5 |
2423 |
|
5x35 |
rm |
0.9 |
1.9 |
34.5 |
3057 |
|
5x50 |
rm |
1.1 |
2.2 |
40.0 |
4099 |
Product Advantages
Structural and Design Efficacy of the N2XRY Armored Cable
The N2XRY armored cable achieves superior mechanical protection through galvanized steel or aluminum wire armoring coupled with an optimized PVC outer sheath. This construction enhances resistance against abrasion, crushing forces, and environmental degradation. The waterproof low voltage cable design incorporates sealed connectors that mitigate water ingress risks, essential for underground power cable applications. Crosslinked polyethylene insulation guarantees stable electrical performance under thermal and mechanical stress. Its modular conductor size range and adherence to stringent standards like IEC 60502-1 and BS5467 provide design flexibility tailored to complex installation requirements encountered by low voltage cable suppliers.
Performance Excellence and Operational Benefits
This product by the N2XRY cable manufacturer offers high insulation resistance and flame retardant properties that ensure safety and longevity in demanding electrical installations. Its operating temperature parameters accommodate harsh climates and high-temperature industrial sites, enhancing system uptime. The cable’s flexibility and conductivity efficiency reduce installation time and operational energy losses. Waterproof connectors secure continuity in damp or underground environments, crucial for minimizing maintenance interventions. The combination of performance, durability, and compliance makes this low voltage cable supplier’s offering an optimal choice for engineering projects focusing on sustainability and regulatory adherence.

Use Scenarios
Underground Power Cable Applications in Urban Infrastructure
In urban development projects, the waterproof low voltage cable performs critically within underground power cable systems that require durable and reliable electrical transmission. The armored design protects against mechanical hazards like soil pressure and excavation activities, while waterproof connectors ensure moisture resistance under variable groundwater conditions. This cable integrates with municipal electrical distribution frameworks, supporting grid resilience and continuity. Its compliance with international testing standards reinforces safety assurance, facilitating straightforward inclusion in power distribution networks serving residential, commercial, and public facilities.
Outdoor Industrial Electrical Installations Requiring Armored Cable Durability
In outdoor industrial environments subject to heavy mechanical and weather-related challenges, N2XRY armored cable provides secure electrical connectivity. It is extensively deployed in factories, petrochemical plants, and transportation terminals where exposure to abrasion, temperature extremes, and water is routine. The low voltage cable supplier’s product withstands these conditions due to its rugged construction and waterproof connectors. Integration into complex industrial wiring systems is optimized by the cable’s standardized dimension ranges and conductor types, ensuring compatibility and maintaining uninterrupted electrical service vital for process efficiency and safety compliance in demanding settings.

What materials are used in the construction of the N2XRY cable?
Our N2XRY armored cable features solid or stranded bare copper conductors insulated with crosslinked polyethylene (XLPE). It is protected by either galvanized steel wire or aluminum wire armoring and encased in a PVC outer sheath, ensuring durability and high mechanical resistance in demanding environments.
Can I customize the conductor sizes for the Jinda Cable N2XRY Low Voltage Cable?
Yes, we offer conductor sizes ranging from 1x1.5 mm² up to 5x50 mm² depending on your project needs. This flexibility allows you to select the appropriate cable configuration while benefiting from reliable performance provided by Jinda as a trusted low voltage cable supplier.
Is the N2XRY cable suitable for underground power cable installations?
Absolutely. Our waterproof low voltage cable includes a specifically designed waterproof connector, making it ideal for underground installations. It withstands moisture and mechanical stress, providing stable and long-lasting power supply in harsh underground environments.
How do you ensure the safety and reliability of Jinda’s N2XRY cable in industrial applications?
We manufacture the N2XRY cable to meet stringent international standards such as IEC 60502-1, VDE 0276-604, and BS5467. It features flame retardant properties according to IEC 60332.1 and high insulation resistance, ensuring consistent and safe electrical performance in industrial and commercial projects.